Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Aust Endod J ; 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37876340

RESUMO

This study evaluated the impact of long-term storage conditions (medium and time) on the development of experimental dentinal microcracks through micro-computed tomography. Sixty freshly extracted premolars were stored in formalin, water, or dry conditions (n = 20) and scanned after 72 h, 30 days, 6 months and 3 years of extraction. The effect of the storage medium and time on the occurrence of dentinal defects was statistically evaluated. A total of 211 000 images were screened revealing the existence of 11 519 slices with dentinal defects. Dry conditions significantly contributed to the development of new defects in all time points. During the 3-year follow-up period, no new defects were detected in the teeth that were stored in water and, in a single tooth, in the formalin group, after 6 months of storage.

2.
Aust Endod J ; 48(1): 72-76, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34494676

RESUMO

This study evaluated the efficacy of sodium thiosulphate (ST) as an intermediate irrigant between sodium hypochlorite (NaOCl) and chlorhexidine (CHX) to avoid the formation of the brown-coloured precipitate. The in vitro experiment used microtubes to test the mixture of 2.5% NaOCl, 2% CHX and 5% ST solutions, varying their order and time of addition. In the ex vivo experiment, 10 bovine teeth were divided into two groups according to the intermediate irrigant used: distilled water (control) and 5% ST (experimental). Colour change occurred in all microtubes after interaction between solutions. While the precipitate was not observed in the experimental group, it was seen in all specimens of the control group. The 5% ST was able to prevent the formation of the brown-coloured precipitate in the ex vivo experiment, whereas it only prevented its in vitro formation when the waiting time for adding CHX was 10, 15 and 20 min.


Assuntos
Clorexidina , Irrigantes do Canal Radicular , Animais , Bovinos , Precipitação Química , Clorexidina/farmacologia , Hipoclorito de Sódio/farmacologia , Tiossulfatos
3.
Braz Oral Res ; 35: e021, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33605352

RESUMO

The aim of the present study was to evaluate the cyclic fatigue, torsional resistance and surface roughness of Reciproc R25 instruments in four different situations, namely as new instruments and as instruments tested after clinical preparation of one, two or three maxillary molars with four root canals. The total time required to perform each root canal preparation was recorded. Cyclic fatigue resistance was determined by the time to fracture using a customized testing device (n = 10 per group). The torsional test evaluated the torque and angle of rotation to failure according to ISO 3630-1 (n = 10 per group). The roughness of the working parts of new and used instruments was evaluated with a profilometer (n = 5 per group). Statistical analysis was performed using one-way ANOVA and Tukey's test. The level of significance was set at 5%. No fractures or deformations were observed after clinical use. Higher preparation time was needed during the third use of the instruments for all root canals (p < 0.05). There were no significant differences among the groups in regard to either cyclic fatigue or torsional resistance (p > 0.05). Regarding the roughness measurements, groove depth was higher on new and one- versus two- or three-maxillary-molar-prepared instruments (p < 0.05). It can be concluded that the clinical use of Reciproc instruments increased preparation time and decreased surface roughness. However, clinical use did not affect the cyclic fatigue or torsional resistance of the Reciproc instruments.


Assuntos
Preparo de Canal Radicular , Titânio , Instrumentos Odontológicos , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Torque
4.
J Endod ; 47(1): 100-104, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33045262

RESUMO

INTRODUCTION: This study assessed the number of mesial and distal canals of mandibular molars in which the R-Pilot pathfinding reciprocating instrument reached the working length (WL) during macro glide path procedure. Fracture and deformation rates were also evaluated. METHODS: One hundred fifty-six root canals of 52 teeth were scouted to the length of the apical foramen. Then the R-Pilot instrument was positioned at the canal orifice and activated. The instrument was moved by using a pecking motion and light apical pressure. This procedure was repeated in an attempt to reach the WL. The type of fracture and/or instrument deformation was assessed by scanning electron microscopy, whereas the roots with fractured instruments were scanned through micro-computed tomography. The percentage frequency distribution of fractures, deformations, and root canals in which the R-Pilot reached the WL were recorded and statistically compared by using the Pearson's χ2 test with α = 5%. RESULTS: R-Pilot instruments reached the WL in 139 root canals (89.10%), and χ2 test showed a significant difference between the observed frequencies and the expected frequencies (χ2 = 95.41, P = .000). The observed frequencies of fractures (2.56%) and deformations (1.92%) were also significantly lower than the expected (fracture: χ2 = 140.41, P = .000; deformation: χ2 = 144.23, P = .000). Fractures occurred mostly at the apical and curved parts of the root canals. CONCLUSIONS: R-Pilot reached the WL in 89.10% of the root canals of mandibular molars with fracture and deformation rates of 2.56% and 1.92%, respectively.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Cavidade Pulpar/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Ápice Dentário , Microtomografia por Raio-X
5.
Clin Oral Investig ; 25(4): 1899-1906, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32789655

RESUMO

OBJECTIVES: To present and explore the potential of an animal-based experimental model developed to determine the set of root canal sealers in vivo. The setting of AH Plus, BioC Sealer, TotalFill BC Sealer, and Sealapex was determined using either ISO 6876 or the novel in vivo method proposed in this study. MATERIAL AND METHODS: The in vitro setting time of the sealers tested was determined in accordance with ISO 6876:2012. In determining the in vivo set, 24 adult Wistar rats were followed up for two evaluation periods: 1 and 4 weeks. Their upper-right incisor was extracted, and its pulp tissue was removed. The root canal was then filled from retrograde with one of the 4 sealers, and the tooth was re-implanted and fixed with a layer of a flowable composite resin. After 1 or 4 weeks of the surgical procedures, the animals were euthanized, and their incisors were extracted. Two-mm-thick slices of the middle third of the tooth root were obtained and assessed with a Gillmore device, to determine whether or not the sealer had set. RESULTS: The following in vitro results were obtained by using ISO 6876 methodology: AH Plus set after a mean time of 423 ± 20 min and 476 ± 35 min, in metal and plaster molds, respectively. BioC Sealer set after 7 days (in dental plaster molds), whereas TotalFill BC Sealer and Sealapex did not set even after 25 days in both tested conditions (metal or dental plaster molds). Using the novel in vivo methodology, AH Plus, BioC Sealer, and TotalFill BC Sealer set after both 7 and 30 days. In contrast, Sealapex did not set at either time point. CONCLUSIONS: AH Plus and BioC Sealer set under both in vitro and in vivo test conditions. TotalFill BC Sealer did not set under in vitro conditions but did after 1 week under in vivo conditions. Sealapex did not set under either in vitro or in vivo conditions. CLINICAL RELEVANCE: The influence of the testing conditions on the setting results is a clear indication that new in vivo experimental models should be useful in future studies on Bioceramics root canal sealers.


Assuntos
Materiais Restauradores do Canal Radicular , Animais , Compostos de Cálcio , Cavidade Pulpar , Resinas Epóxi , Teste de Materiais , Modelos Teóricos , Ratos , Ratos Wistar , Silicatos
6.
Clin Oral Investig ; 25(6): 3641-3649, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33236240

RESUMO

OBJECTIVES: This study evaluated the danger zone (DZ) in mesial roots of mandibular molars and the correlation between anatomical references of the DZ and some anatomical landmarks including tooth/root length, depth of mesial and distal grooves, and inter-canal orifices distance. MATERIAL AND METHODS: Twenty-eight mesial roots of mandibular molars with 2 independent canals were scanned and divided into 2 groups according to root length. The anatomical landmarks were correlated (Pearson or Spearman coefficients) with root level, thickness, and position of the DZ and also compared (independent samples t or Mann-Whitney tests) between the 2 groups at α = 5%. RESULTS: No statistical difference was observed between groups regarding DZ parameters and depth of mesial and distal grooves (P > 0.05). Orifice distance in group 2 (4.49 ± 0.75 mm) was significantly greater than group 1 (3.76 ± 0.89 mm) (P < 0.05). Significant correlations (P < 0.05) were found between (i) DZ level and root/tooth length (r = 0.54 and 0.49, respectively), (ii) DZ thickness and distal groove depth (r = - 0.45), and orifice distance (r = 0.38), and (iii) DZ position and depth of mesial (r = 0.39) and distal (r = 0.40) grooves. Other variables such as root length and distal groove depth (r = 0.28), and orifice distance and mesial groove depth (r = 0.36) were also correlated (P < 0.05). CONCLUSIONS: The length of tooth/root, the distance of canal orifices, and the depth of mesial/distal grooves of mesial roots of mandibular molars might be predictive factors for the root level, position, and thickness of the DZ. CLINICAL RELEVANCE: The length, distance of mesial canal orifices, and the depth of mesial and distal grooves of the mesial roots of mandibular molars might be moderate predictive factors for the root level, position, and thickness of the DZ.


Assuntos
Mandíbula , Raiz Dentária , Cavidade Pulpar/diagnóstico por imagem , Mandíbula/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem
7.
Braz. oral res. (Online) ; 35: e021, 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1153624

RESUMO

Abstrac The aim of the present study was to evaluate the cyclic fatigue, torsional resistance and surface roughness of Reciproc R25 instruments in four different situations, namely as new instruments and as instruments tested after clinical preparation of one, two or three maxillary molars with four root canals. The total time required to perform each root canal preparation was recorded. Cyclic fatigue resistance was determined by the time to fracture using a customized testing device (n = 10 per group). The torsional test evaluated the torque and angle of rotation to failure according to ISO 3630-1 (n = 10 per group). The roughness of the working parts of new and used instruments was evaluated with a profilometer (n = 5 per group). Statistical analysis was performed using one-way ANOVA and Tukey's test. The level of significance was set at 5%. No fractures or deformations were observed after clinical use. Higher preparation time was needed during the third use of the instruments for all root canals (p < 0.05). There were no significant differences among the groups in regard to either cyclic fatigue or torsional resistance (p > 0.05). Regarding the roughness measurements, groove depth was higher on new and one- versus two- or three-maxillary-molar-prepared instruments (p < 0.05). It can be concluded that the clinical use of Reciproc instruments increased preparation time and decreased surface roughness. However, clinical use did not affect the cyclic fatigue or torsional resistance of the Reciproc instruments.


Assuntos
Titânio , Preparo de Canal Radicular , Estresse Mecânico , Teste de Materiais , Torque , Instrumentos Odontológicos , Desenho de Equipamento
8.
J Adhes Dent ; 18(2): 157-60, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27022643

RESUMO

PURPOSE: To investigate the resistance to dislodgment produced by Biodentine (Septodont) and White-MTA (Angelus) after immersion in phosphate-buffered saline (PBS) for different durations. MATERIALS AND METHODS: Dentin disks 1 ± 0.1 mm thick were obtained from the middle third of the roots of 6 human maxillary canines. On the coronal surface of each dentin disk, four 0.8-mm-diameter holes were drilled. Then the slices were halved using a low-speed saw diamond disk, and the two holes in each half were filled with one of the two tested materials. Each filled half was immersed in PBS solution (pH 7.2) either for 7 days (short term) or 60 days (long term) at 37°C. The push-out test was performed after both time periods. A general linear model (GLM) for repeated measures ANOVA was used to verify the effect of the material and duration of contact with PBS on the push-out strength. The material was considered as the within-subject contrast and the contact duration as the between-subjects effect (p < 0.05). RESULTS: Repeated measures GLM indicated a significant impact of material and time on the push-out strength of the samples (p = 0.000 and p = 0.033, respectively). Biodentine significantly improved the push-out strength compared to MTA at both times (p = 0.000). The lack of significance in the interaction between material and time indicates that PBS immersion positively influenced the push-out values of both tested materials. CONCLUSION: Long-term PBS immersion positively influenced the resistance to dislodgement from dentin of all cements tested. The Biodentine cement provided greater resistance to push-out force than did the MTA.


Assuntos
Compostos de Cálcio/química , Colagem Dentária , Cimento de Silicato/química , Silicatos/química , Bismuto/química , Cimentos Dentários/química , Cavidade Pulpar/ultraestrutura , Análise do Estresse Dentário/instrumentação , Dentina/ultraestrutura , Humanos , Imersão , Teste de Materiais , Óxidos/química , Distribuição Aleatória , Cloreto de Sódio/química , Estresse Mecânico , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...